1、太阳能光伏系统蓄电池充电中英文对照外文翻译文献 (文档含英文原文和中文翻译)中英文对照外文翻译Design of a Lead-Acid Battery Charging and Protecting IC in Photovoltaic System1.IntroductionSolar energy as an inexhaustible, inexhaustible source of energy more and more attention. Solar power has become popular in many countries and regions, solar li
2、ghting has also been put into use in many cities in China. As a key part of the solar lighting, battery charging and protection is particularly important. Sealed maintenance-free lead-acid battery has a sealed, leak-free, pollution-free, maintenance-free, low-cost, reliable power supply during the e
3、ntire life of the battery voltage is stable and no maintenance, the need for uninterrupted for the various types of has wide application in power electronic equipment, and portable instrumentation. Appropriate float voltage, in normal use (to prevent over-discharge, overcharge, over-current), mainte
4、nance-free lead-acid battery float life of up to 12 16 years float voltage deviation of 5% shorten the life of 1/2. Thus, the charge has a major impact on this type of battery life. Photovoltaic, battery does not need regular maintenance, the correct charge and reasonable protection, can effectively
5、 extend battery life. Charging and protection IC is the separation of the occupied area and the peripheral circuit complexity. Currently, the market has not yet real, charged with the protection function is integrated on a single chip. For this problem, design a set of battery charging and protectio
6、n functions in one IC is very necessary.2.System design and considerationsThe system mainly includes two parts: the battery charger module and the protection module. Of great significance for the battery as standby power use of the occasion, It can ensure that the external power supply to the batter
7、y-powered, but also in the battery overcharge, over-current and an external power supply is disconnected the battery is to put the state to provide protection, the charge and protection rolled into one to make the circuit to simplify and reduce valuable product waste of resources. Figure 1 is a spec
8、ific application of this Ic in the photovoltaic power generation system, but also the source of this design.accumulatorDC loadcontroller Discharge controllerChargecontrollersolar battery arrayFigure1 Photovoltaic circuit system block diagram Maintenance-free lead-acid battery life is usually the cyc
9、le life and float life factors affecting the life of the battery charge rate, discharge rate, and float voltage. Some manufacturers said that if the overcharge protection circuit, the charging rate can be achieved even more than 2C (C is the rated capacity of the battery), battery manufacturers reco
10、mmend charging rate of C/20 C/3. Battery voltage and temperature, the temperature is increased by 1 C, single cell battery voltage drops 4 mV, negative temperature coefficient of -4 mV / C means that the battery float voltage. Ordinary charger for the best working condition at 25 C; charge less than
11、 the ambient temperature of 0 C; at 45 C may shorten the battery life due to severe overcharge. To make the battery to extend the working life, have a certain understanding and analysis of the working status of the battery, in order to achieve the purpose of protection of the battery. Battery, there
12、 are four states: normal state, over-current state over the state of charge, over discharge state. However, due to the impact of the different discharge current over-capacity and lifetime of the battery is not the same, so the battery over discharge current detection should be treated separately. Wh
13、en the battery is charging the state a long time, would severely reduce the capacity of the battery and shorten battery life. When the battery is the time of discharge status exceeds the allotted time, the battery, the battery voltage is too low may not be able to recharge, making the battery life i
14、s lower. Based on the above, the charge on the life of maintenance-free lead-acid batteries have a significant impact, while the battery is always in good working condition, battery protection circuit must be able to detect the normal working condition of the battery and make the action the battery
15、can never normal working state back to normal operation, in order to achieve the protection of the battery.3.Units modular design 3.1The charging moduleChip, charging module block diagram shown in Figure 2. The circuitry includes current limiting, current sensing comparator, reference voltage source
16、, under-voltage detection circuit, voltage sampling circuit and logic control circuit.Voltage sampling comparatorUndervoltage detection circuitR- powerVoltage amplifierPower indicatorLimiting amplifierCurrent samplingcomparatorLogical moduleCharging indicatorState level controlStart amplifierdriverF
17、igure2 Charging module block diagram The module contains a stand-alone limiting amplifier and voltage control circuit, it can control off-chip drive, 20 30 mA, provided by the drive output current can directly drive an external series of adjustment tube, so as to adjust the charger output voltage an
18、d current . Voltage and current detection comparator detects the battery charge status, and control the state of the input signal of the logic circuit. When the battery voltage or current is too low, the charge to start the comparator control the charging. Appliances into the trickle charge state wh
19、en the cut-off of the drive, the comparator can output about 20 mA into the trickle charge current. Thus, when the battery short-circuit or reverse, the charger can only charge a small current, to avoid damage to the battery charging current is too large. This module constitutes a charging circuit c
20、harging process is divided into two charging status: high-current constant-current charge state, high-voltage charge status and low-voltage constant voltage floating state. The charging process from the constant current charging status, the constant charging current of the charger output in this sta
21、te. And the charger continuously monitors the voltage across the battery pack, the battery power has been restored to 70% to 90% of the released capacity when the battery voltage reaches the switching voltage to charge conversion voltage Vsam charger moves to the state of charge. In this state, the
22、charger output voltage is increased to overcharge pressure Voc is due to the charger output voltage remains constant, so the charging current is a continuous decline. Current down to charge and suspend the current Ioct, the battery capacity has reached 100% of rated capacity, the charger output volt
23、age drops to a lower float voltage VF. 3.2 Protection ModuleChip block diagram of the internal protection circuit shown in Figure 3. The circuit includes control logic circuit, sampling circuit, overcharge detection circuit, over-discharge detection comparator, overcurrent detection comparator, load
24、 short-circuit detection circuit, level-shifting circuit and reference circuit (BGR).Over-current detection comparator2Load short detection circuitOver-current detection circuitOver-current detection comparator1Overcharge detection comparatorLevel conversioncircuitControl logic circuitOver discharge
25、detection comparatorSampling circuitFigure3 Block diagram of battery protectionThis module constitutes a protection circuit shown in Figure 4. Under the chip supply voltage within the normal scope of work, and the VM pin voltage at the overcurrent detection voltage, the battery is in normal operatio
26、n, the charge and discharge control of the chip high power end of the CO and DO are level, when the chip is in normal working mode. Larger when the battery discharge current will cause voltage rise of the VM pin at the VM pin voltage at above the current detection voltage Viov, then the battery is t
27、he current status, if this state to maintain the tiov overcurrent delay time, the chip ban on battery discharge, then the charge to control the end of CO is high, the discharge control side DO is low, the chip is in the current mode, general in order to play on the battery safer and more reasonable
28、protection, the chip will battery over-discharge current to take over the discharge current delay time protection. The general rule is that the over-discharge current is larger, over the shorter the discharge current delay time. Above Overcharge detection voltage, the chip supply voltage (Vdd Vcu),
29、the battery is in overcharge state, this state is to maintain the corresponding overcharge delay time tcu chip will be prohibited from charging the battery, then discharge control end DO is high, and charging control terminal CO is low, the chip is in charging mode. When the supply voltage of the ch
30、ip under the overdischarge detection voltage (Vdd Vdl,), then the battery is discharged state, this state remains the overdischarge delay time tdl chip will be prohibited to discharge the battery at this time The charge control side CO is high, while the discharge control terminal DO is low, the chi
31、p is in discharge mode.Protection moduleFigure4 Protection circuit application schematic diagram4.Circuit Design Two charge protection module structure diagram, the circuit can be divided into four parts: the power detection circuit (under-voltage detection circuit), part of the bias circuit (sampli
32、ng circuit, the reference circuit and bias circuit), the comparator (including the overcharge detection /overdischarge detection comparator, over-current detection and load short-circuit detection circuit) and the logic control part.This paper describes the under-voltage detection circuit (Figure 5), and gives the bandgap reference circuit (Figure 6).Output circuitdifferenceamplifierBleeder circuitReference circuitBiasing circuitFigure5 Under-voltage detection circuitAmplifier Amplifier Figure6 A reference p