1、SAS Controller CardHP-UX and OpenVMSRAID 1PCI-XSmart Array P400HP-UX, OpenVMS, Windows and LinuxRAID 1 ,RAID 5 ,RAID 6PCI EXPRESSSmart Array P600Windows and LinuxSmart Array P800Windows1.2. 所以再考虑作硬raid时,我们应考虑如下因素3. 操作系统(HP-UX, OpenVMS, Windows or Linux)4. Raid类型(0,1,5,6)5. Raid卡类型(PCI-x or PCI-e)6.
2、主机的I/O board 类型是否支持PCI-e使用SAS Controller Card 配置硬raid1.3. 重启主机进入EFI界面二、选择EFI Shell Built-in 进入shellSearching for devicesLoading.: EFI Shell Built-inEFI Shell version 2.00 14.62Device mapping table fs0 : Acpi(HWP0002,PNP0A03,400)/Pci(1|0)/Sas(Addr5000C500082310F9,Lun0)/HD(Part1,Sig17DCDF48-B064-11DC-
3、8002-D6217B60E588) fs1 :rt3,Sig17DCDF7A-B064-11DC-8004-D6217B60E588) blk0 : Acpi(HWP0002,PNP0A03,0)/Pci(2|1)/Usb(0, 0) blk1 : Acpi(HWP0002,PNP0A03,400)/Pci(1|0)/Sas(Addr5000C500082310F9,Lun0) blk2 : blk3 :rt2,Sig17DCDF5C-B064-11DC-8003-D6217B60E588) blk4 : blk5 : Acpi(HWP0002,PNP0A03,400)/Pci(1|0)/S
4、as(Addr5000C50008233309,Lun0)startup.nsh echo -off setting hpux path(EFIHPUX). type fsx: where x is your bootdisk (0, 1, 2.) hpux to start hpux bootloader 1.4. 输入devtreeShell devtree /显示设备列表Device Tree Ctrl04 Ctrl08 VenHw(SysROM) Ctrl10 Acpi(HWP0002,PNP0A03,0) Ctrl1B Acpi(HWP0002,PNP0A03,0)/Pci(1|0)
5、 Ctrl1C Acpi(HWP0002,PNP0A03,0)/Pci(1|1) Ctrl1D Acpi(HWP0002,PNP0A03,0)/Pci(1|2) Ctrl42 16550 Serial UART Ctrl43 VT-100+ Serial Console Ctrl3C Primary Console Input Device Ctrl3D Primary Console Output Device Ctrl3B Primary Standard Error Device Ctrl1E Usb Open Host Controller Ctrl44 Generic Usb Key
6、board Ctrl45 Acpi(HWP0002,PNP0A03,0)/Pci(2|0)/Usb(0, 1) Ctrl1F Usb Open Host Controller Ctrl46 Usb Bot Mass Storage Ctrl20 Acpi(HWP0002,PNP0A03,0)/Pci(2|2) Ctrl21 Acpi(HWP0002,PNP0A03,0)/Pci(4|0) Ctrl11 Acpi(HWP0002,PNP0A03,100) Ctrl12 Acpi(HWP0002,PNP0A03,200) Ctrl13 Acpi(HWP0002,PNP0A03,300) Ctrl2
7、3 Acpi(HWP0002,PNP0A03,300)/Pci(1|0) Ctrl68 Intel(R) PRO/1000 MT Server Connection Ctrl14 Acpi(HWP0002,PNP0A03,400) Ctrl27 LSI Logic SAS Controller /硬盘的控制器 Ctrl67 HP DG146ABAB4 HPDA CtrlA9 FAT FAT32 500 MB CtrlAA Acpi(HWP0002,PNP0A03,400)/Pci(1|0)/Sas(Addr5000C500082310F9,Lun0)/HD(Part2,Sig17DCDF5C-
8、B064-11DC-8003-D6217B60E588) CtrlAB FAT FAT32 400 MB Ctrl69 HP DG146ABAB4 HPDA Ctrl28 Acpi(HWP0002,PNP0A03,400)/Pci(2|0) Ctrl6A Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Mac(001A4B079606) Ctrl29 Acpi(HWP0002,PNP0A03,400)/Pci(2|1) Ctrl6B Acpi(HWP0002,PNP0A03,400)/Pci(2|1)/Mac(001A4B079607) Ctrl15 Acpi(HWP00
9、02,PNP0A03,500) Ctrl16 Acpi(HWP0002,PNP0A03,600) Ctrl17 Acpi(HWP0002,PNP0A03,700) Ctrl2B Acpi(HWP0002,PNP0A03,700)/Pci(1|0) Ctrl6C Intel(R) PRO/1000 MT Server Connection Ctrl64 VenHw(D65A6B8C-71E5-4DF0-A909-F0D2992B5AA9) Ctrl66 Acpi(HWP0002,PNP0A03,400)/Pci(1|0)/Ctrl(0)1.5. 输入drvcfg找出控制器所对应的驱动号码 drv
10、cfgConfigurable Components Drv24 Ctrl27 Langeng Drv2C Ctrl44 Langeng1.6. drvcfg -s 24 27进行配置,出现如下窗口 drvcfg -s 24 27 /进行配置,出现如下窗口1.7. 配置选中,回车选择红色标示的选项,进入下一界面:1.8. 选中该选项,进入下一界面:1.9. 直接输入M,进行修改RAID DISK 状态变成yes,选中下面一块磁盘的RAID DISK 选项,进入下一界面直接回车,两块磁盘的RAID DISK 状态均变为 yes ,退出,进入下一界面选择保存设置退出,配置完毕!Smart Arra
11、y Card做硬raid(orac)Orac出现在安腾系列主机启动EFI shell的过程中,当看到提示按F8进入orac时按F8进入(注意如果是非标准键盘输入,比如用笔记本串口连接,用Esc+8代替F8)进入orac后看到以下画面:1.10. 创建logical drive:选中create logical drive 进入创建raid过程。选择图1中Create Logical Drive进入图2在上图中我们可以看到,左边Available Physical Drives选择框中就是我们物理上连接在需要配置的raid卡上的物理盘,可以选择要对哪几块盘做操作,在Raid Configurations 选择框中可以选择要作的raid级别,在这里3块盘以上可以做Raid5,2块盘以上可以做raid1+0,或只做raid0,Spare中可以用一块盘做hot spare盘(raid知识请查看相关资料)。选择完毕后按Enter创建logical drive,提示下图:按F8(Esc+8)确定配置,这样我们就配置好了,显示下图。1.11. 删除logical drive:进入配置界面,选择Delete Logical Drive选择要删除的logical drive按F8(Esc + 8)删除,然后按F3 (Esc + 8)确定1.12. 查看logical drive: