032架设施工方案englishREV1.docx
《032架设施工方案englishREV1.docx》由会员分享,可在线阅读,更多相关《032架设施工方案englishREV1.docx(9页珍藏版)》请在冰点文库上搜索。
![032架设施工方案englishREV1.docx](https://file1.bingdoc.com/fileroot1/2023-4/30/159a9191-b160-42d7-87bb-ded8148dc137/159a9191-b160-42d7-87bb-ded8148dc1371.gif)
032架设施工方案englishREV1
YPC-BASFCompanyLtd.IPSProject
BCC600,000t/yEthylenePlant
Support
ConstructionProcedure
(REV1)
BASF-YPCEthyleneProjectManagementDept.
TheFourthConstructionCompanyofSINOPEC
Code:
FCC-BCC/Procedure-032
Important
Comprehensive
√
General
YPC-BASFCompanyLtd.IPSProject
BCC600,000t/yEthylenePlant
Support
ConstructionProcedure
(REV1)
Preparedby:
LiWeifeng
Reviewedby:
XuJianling
Approvedby:
GaoHongyan
BASF-YPCEthyleneProjectManagementDept.
TheFourthConstructionCompanyofSINOPEC
19May2003
TableofContent
1Projectinduction1
2Constructionbasis1
3Constructionprocedure1
4Constructiontechnicalrequirement2
5Scaffoldcalculation4
6HSEmeasure7
1Projectinduction
ScaffoldinBASF-YPECethyleneplantcanbeinthreesectionsaccordingtoheight:
:
scaffoldwithheightunder24miswidelyusedonsite,anddonotneedstabilitycalculationaccordingtoconstructionregulation;attachedcolumndoublelinesupportwithheightinrange24m<H≤50m,shallcalculateaxesstability;scaffoldwithheightover50mshallcalculateseparately.
Atpresent,plantswithheight24m<H≤50m,aremainlysupportedinAkindcolumn.
2Constructionbasis
1)《requirementanddesigncalculationoffastenersteeltubescaffoldsupport》JGJ130-2001
2)《constructionsafetytechniqueregulationofpetrochemicalenterprise》SH3505-1999
3Constructionprocedure
4Constructiontechnicalrequirement
4.1Grounddisposal
1)Beforesupport,tampground,increasethedensityofearthandstrengthengroundsupportload.Laysillorsteelboardtoconfirmgroundsupportload.Whengroundtamping,groundnearfoundationshallbehigherthanadjoiningplacetopreventlow-lyingwhenrainingandaffectwholestabilityofsupport.
2)Laypostbaseplatebeforesupport;insertpostonbaseplatetoexpandstrengthareaandsupportstability.
3)supportmaterialsadoptionsshalladheretothefollowingrequirements:
a)supportpoleismadeofsteeltubewithφ48mm,3.5mmthicksteeltubeandinqualityaccordancewithGB7008-79tosteelQ-235Ab)BuckleismadeofforgingcastironintypeofKT-33-8,fastenedboltismadeofsteelinqualityofQ-235A.c)ScaffoldboardismadeofsteelinqualityofQ-235Awithwidthnotlessthan2mm。
4.2Generalrequirementofscaffoldsupport
1)Whensupport,trytosupportindoublelinesupporttoconfirmsupportstability.Insidesupportpoleshallkeepcertaindistancewithcolumnwallandthelessdistanceshallbemorethancolumninsulationthickness+100mm。
2)Supportshallbetidyandinorder:
postandrailshallbeputuniformlywithpostinaverticallineandrailinhorizontal.Sweepingpoleshallsupportinverticalandhorizontalwith200mmhigherthanground.Verticalspaceofpostis.8~2mandhorizontalspacenotmorethan1.3m;walkspaceofbigrailisn’tmorethan1.8m.
3)Whensupporting,shallputapartenoughworksurfacesupportedbyscaffoldboard.Whensupportingscaffoldboardsidebyside,shallbenotlessthan2blocks,prohibitingusingsinglescaffold.Spaceofworklayershallbe1.6m~1.8m.
4)Scaffoldboardfixingshalladheretothefollowingrequirements:
a)Whensupportingscaffolding,besidesconnectingwithsupportpolefast,boardshallbecloseandconnectedbyironwire.Verticalscaffoldboardshalljointogetherwithlengthnotlessthan300mm.b)Use10#~14#galvanizedironwireforconnectionandfixofscaffoldboard.Ironwirejointshallbesetinsideorundersideofscaffoldboard;surfaceshallnotappearironwire.c)Whenfixingscaffoldboard,besidestyingfastwithrails,boardshallbeconnectedsidebyside.
5)Setdoublelayersbarriersonworklayerswithheightofbaserailnotmortthan200mm,antspacebetweentwobarriersnotmorethan1000mm.
6)Whenhavinglocalwork,twoendsofworklayersshallsetbarriers.Inspecialcondition,shallsetsafetynetonundersideorsidetopreventfallings.
7)Setupanddownpathoneveryworksurface.Afterinstallingladdersonplatform,useladderaspathdirectly.Forpartswithoutladder,shallsettemporaryladderwithprotectioncageandshalltiefastwithironwireandconnectwithsupportpole.Additionally,shallsetbarriersonsideofjoints.
8)Whensupportingscaffold,trytoavoidsupportingpostorrailinsideladdersothataffectpassingorworker.
9)Forhighercolumnandgreatweightofscaffold,postbearsmuchstrengthononesidebase,ifaddtheweightofworkersandothermaterials,thestrengthwillincrease,sowhensupportinginhigh,shalluseladders,platforms,pipesupportandoverhangingbeamassupportpoint,removemuchweighttocolumnsoastoincreasingthesupportstabilityandusingthemformediumandsmallsupport.(includeliftingsupportandhangingsupport)
10)Whensupportsurfaceisnotinsideofladderplatform,cansetbridgingaboutevery6moutsidedoublelinesupport.Fixthesoffitwithladderplatformorbrackettoincreasewholescaffoldstability.
11)Whensupportinginhigh(generalheight>24m),shallaccordwithdensityofladderplatform,pipeshoeandpipesupporttodecidewhetherneedtosetbridgingsoastoconfirmthewholesupportstability.
4.3Acceptance
1)Afterscaffoldcompletion,aqualifiedscaffoldershallinspectallscaffoldsandinspectcontentoftrustdeed;Ifeligible,reportittoHSEstationorganizingacceptance.
2)HSEstation,supportunitsandusingunitshaveunitedinspection,ifeligible,signagreementandhangsafe/unsafesymbol.
3)Inspectionshallbedoneonaregularbasis(minimumweekly)
4.4Constructiongistofroofscaffold
Takethesecondlayerplatformofroofaslocatedbase;supporttwo#supports(onbothside).Taketheconnectionpoleof#supportsasfulcrumandjoinroofplatformsintoroofoperationplatform.
5Scaffoldcalculation
Calculationcanbethreeconditions:
ifheightisover50m,calculateseparatelyanddeliverinletters;speciallysupportroofoperationplatform,calculaterootageplatformsupportstrengthandpoststability.Ifdoublelinescaffoldwithheightof24m<H≤50mwhosemicro-cellis#support,calculaterelatedindexofthis#support.
5.1Accountingprocessofroofspecialsupport
ExampleforC-540column,accountsecurityofallcolumnsroofsupport.
5.1.1Load
1)worker:
5persons,about5×70kg=3.5kN
2)scaffoldboard:
about6(block)×25kg=1.5kN
3)supportpost:
about150(m)×3.84kg=5.76kN
4)totalload:
about3.5+1.5+5.76=10.76(kN)
5.1.2“#”Support
Usescaffoldboardforfillingthebaseandexpandingcontactarea.
Totalarea:
0.25×3×4=3(m2)
5.1.3Stabilitycalculationofaxespresspost
σ=N/φ/A≤ſ
N——calculateaxesstrengthdesignNo.ofpostsection
φ——stablemodulusofaxespresspole,
A——postsectionalarea,
ſ——designNo.ofsteelantipressstrength(205N/mm2)
5.1.4Calculation
N=1.2*(1.5+5.76)+1.4×3.5=13.612kN
A=singlepostsectionalarea=489/mm2
φ——byreferredtoλ=K×μ×h/i=1.155*1.5*180/1.58=197
byreferredto(JGJ130-2001)list6:
φ=0.186
σ=N/φ/A=13612/0.186/489/8=18.7N/mm2≤ſ=205N/mm2
5.1.5Conclusion
Wholesupportisstablebyabovestabilitycalculation.
Additionally,fix#supportandroofplatformwithdragbartoincreasewholestabilityofsupport.
5.1.6Strengthcalculationofplatform
1)Pressureof“#”supporttoplatform:
σ=N/A=10.76/3=3.58kN/m2
2)AccordingtoPS-D50-R.1item2.1.5contenta:
vesselplatformstrengthis4.0kN/m2
3)σ=N/A=10.76/3=3.58kN/m2≤4.0kN/m2
4)conclusion:
C-540columnplatformcanfitfortherequirementofsupportconstruction.
5)Additionally,realsupportareaofC-540columnplatformis3m×columnplatformwidth1.1m×2=6.6m2,workingload10.76kNfarlessthancolumnsupportcapacity(6.6m2×4kN/m2)26.4kN。
5.1.7Insummarization,roofsupportofallcolumnsisbasicallysimilartoC-540andstrengthcalculationissafe.
5.2Calculationprocessofattachedcolumndoublelinesupport
5.2.1Load
1)Worker:
2persons,about2×70kg=1.4kN
2)Scaffoldboard:
about40(block)×25kg=10kN
3)Buckle:
80×0.0015=0.12kN
4)Supportpost:
about420(m)×3.84kg=16.128kN
5)Totalload:
about3.5+1.5+5.76=27.648(kN)
5.2.2Supportcapacityofscaffoldfoundation
Tampingbackfill:
49~78kN/m2
5.2.3Doublelinesupport
Usesteelscaffoldboardforfillingbaseandexpandingcontactareawithheightabout50m.Usecircular-likedoublelinesupportofdoublepipepostwithabout22layersworkingsurface.MaincolumnsareC-360、C-210、C-530withtheirmicro-cellsof#support.
Usesteelscaffoldboardformicro-cell#supportcontactingground.Thecontactareais2×0.25×3=1.5(m2)
5.2.4Stabilitycalculationofaxespresspost:
σ=N/φ/A≤ſ
N——calculateaxesstrengthdesignNo.ofpostsection
φ——stablemodulusofaxespresspole,
A——postsectionalarea,
ſ——designNo.ofsteelantipressstrength(205N/mm2)
5.2.5Calculation
N=1.2*(10+0.12+16.128)+1.4×1.4=33.4576kN
A=singlepostsection=489/mm2,total4postsof#support,totalareais489*4
φ——byreferredtoλ=k×μ×h/i=1.155*1.55*190/1.58=215
hispostwalkspace~1.9m。
byreferredto(JGJ130-2001)list4:
i=1.58cm
byreferredto(JGJ130-2001)list5:
μ=1.55
byreferredto(JGJ130-2001)list6:
φ=0.157
σ=N/φ/A=33457.6/0.157/489/4=108.95N/mm2≤ſ=205N/mm2
5.2.6Calculation
Supportofdoublesupportover50misstablebyabovestabilitycalculation.
Additionally,fixdoublesupportandroofplatformwithdragbartoincreasewholestabilityofsupport.
5.2.7Foundationstrengthcalculation
1)Pressureofdoublesupportmicro-celltogroundis:
2)σ=N/A=27.648/1.5=18.432kN/m2
3)Accordingto《constructionfoundationdesignspecification》GBJ749~78kN/m2
4)σ=N/A=27.648/1.5kN/m2=18.432kN/m2<49~78kN/m2
5)Conclusion:
thefoundationcanfitfortherequirementofsuchkindsofsupport.