2003年11月
II
第一章概述.....................................................................1
1研制过程.....................................................................1
2主要技术特点.................................................................1
3系统主要技术条件.............................................................1
3.1环境条件..................................................................1
3.2发送器....................................................................1
3.3接收器....................................................................2
3.4直流电源..................................................................2
3.5轨道电路..................................................................2
3.6系统冗余方式..............................................................2
第二章系统的构成及原理说明.......................................................3
1系统的构成....................................................................3
1.1室外部分..................................................................3
1.2室内部分..................................................................4
1.3系统防雷..................................................................4
2ZPW-2000A型无绝缘移频自动闭塞系统电路原理....................................5
2.1电气绝缘节................................................................5
2.1.1作用..................................................................5
2.1.2简要工作原理..........................................................5
2.1.3电气绝缘节电路环节分析和计算..........................................6
2.1.4BA参数举例及分析......................................................8
2.1.5调谐区阻抗频率特性....................................................9
2.1.6BA工作稳定性..........................................................9
2.1.7空心线圈..............................................................9
2.1.8机械绝缘空心线圈.....................................................10
2.1.9匹配变压器...........................................................11
2.2发送器...................................................................11
2.2.1作用.................................................................11
2.2.2原理框图及电原理说明.................................................12
2.2.3发送器“N+1”冗余系统原理............................................16
2.3接收器...................................................................17
2.3.1作用.................................................................17
2.3.2原理框图及原理说明...................................................17
2.3.3接收器双机并联运用原理...............................................21
2.4衰耗盘...................................................................23
2.4.1作用.................................................................23
2.4.2衰耗盘外形示意图.....................................................23
2.4.3衰耗盘面板布置图.....................................................23
2.4.4电原理说明...........................................................23
2.4.5衰耗盘端子用途说明...................................................27
2.4.6衰耗盘外线连接.......................................................28
2.5电缆模拟网络盘...........................................................29
2.5.1作用.................................................................29
III
2.5.2电缆模拟网络盘外形及构成示意图......................................29
2.5.3原理框图.............................................................29
2.5.4防雷电路原理简要说明.................................................29
2.5.5电缆模拟网络电路原理简要说明.........................................30
2.6补偿电容作用及原理.......................................................31
2.7站内电码化..............................................................32
2.7.125Hz相敏轨道电路预叠加ZPW-2000A电码化技术条件.......................32
2.7.2ZPW2000-A预叠加电码化设计说明........................................32
2.7.3电码化发送检测盘.....................................................33
2.7.4举例设计.............................................................35
第三章主要技术指标..............................................................43
1室内设备.....................................................................43
1.1发送器...................................................................43
1.2接收器...................................................................43
1.3衰耗盘...................................................................44
1.4电缆模拟网络盘...........................................................44
2室外设备.....................................................................45
2.1匹配变压器(TAD)........................................................45
2.2空心线圈(SVA............................................................45
2.3机械绝缘空心线圈(SVA’)................................................45
2.4调谐单元(BA)...........................................................46
2.5补偿电容.................................................................46
第四章安装与维护................................................................47
1技术人员的应知应会...........................................................47
2移频柜.......................................................................48
2.1移频柜组成...............................................................48
2.2端子占用分配表...........................................................49
2.3区间移频柜组合类型:
....................................................53
3网络接口柜..................................................................53
4主要表示、检查部位及测量值...................................................53
4.1闭塞分区编号及移频柜设备位置的排列.......................................53
4.2设备故障的三级报警指示设计...............................................54
4.3主要表示灯...............................................................54
4.4主要测试插孔.............................................................55
5开通试验步骤.................................................................56
5.1开通试验前准备工作.......................................................56
5.2开通试验.................................................................56
6系统故障分类及处理办法.......................................................57
6.1断线.....................................................................57
6.2混线.....................................................................57
6.3接地.....................................................................58
7故障处理程序.................................................................58
7.1一般有报警故障处理程序...................................................58
7.2无报警故障处理程序.......................................................58
8对工程防雷设计及施工的意见...................................................58
9对工程室内配线的建议.........................................................59
IV10常用维修测试仪表............................................................59
10.1CD96-3型UM71参数选频测试表.............................................59
10.2CD96-3A型UM71/YP多用测试表.............................................60
10.3HP8904A频率合成器.......................................................61
10.41250A频响分析仪.........................................................61
10.5BOP100-4M型.............................................................62
11ZPW-2000A轨道电路调整表.....................................................62
附表11700Hz轨道电路调整表.................................................63
附表22000Hz轨道电路调整表.................................................64
附表32300Hz轨道电路调整表.................................................65
附表42600Hz轨道电路调整表.................................................66
附表5电缆模拟网络电缆补偿长度调整表........................................67
附表6发送器载频调整表......................................................68
附表7发送器带载输出电平级调整表............................................68
附表8接收器载频调整........................................................69
附表9接收器电平级调整表....................................................70
附表10不同长度的小轨道的电平级调整表........................................1
附表11ZPW-2000A无绝缘移频自动闭塞系统设备清单.............................8
1
第一章概述
1研制过程
ZPW-2000A型无绝缘移频自动闭塞系统是在法国UM71无绝缘轨道电路技术引进、国产化基础上,结合国情进行的技术再开发。
前者较后者在轨道电路传输安全性、传输长度、系统可靠性、可维修性以及结合国情提高技术性能价格比、降低工程造价上都有了显著提高。
该系统自1998年开始研究。
2000年10月底,针对郑州局、南昌局接连两次发生因钢轨电气分离式断轨,轨道电路得不到检查,客车脱轨的重大事故,该系统提出了解决“全程断轨检查”等四项提高无绝缘轨道电路传输安全性的技术创新方案,获得了铁道部运输局、科技司的肯定。
2001年,针对郑-武UM71轨道电路雨季多处“红光带”,该系统围绕“低道碴电阻道床雨季红光带”问题,通过对轨道电路计算机仿真系统的开发,提出了提高轨道电路传输性能的一系列技术方案,从理论和实践结合上实现了传输系统的技术优化。
2002年5月28日,该系统通过铁道部技术鉴定,确定推广应用。
2002年10月17日至今,该系统对适用于地下铁道短调谐区ZPW-2000技术方案进行了运用试验,情况良好。
ZPW-2OOOA无绝缘轨道电路由较为完备的轨道电路传输安全性技术及参数优化的传输系统构成。
国家知识产权局已受理了有关“钢轨断轨检查”、“多路移频信号接收器”²
²
等8项专利,成为我国目前安全性高、传输性能好、具有自主知识产权的一种先进自动闭塞制式,为“机车信号做为主体信号”创造了必备的安全基础条件。
2主要技术特点
1充分肯定、保持UM71无绝缘轨道电路整体结构上的优势。
2解决了调谐区断轨检查,实现轨道电路全程断轨检查。
3减少调谐区分路死区。
4实现对调谐单元断线故障的检查。
5实现对拍频干扰的防护。
6通过系统参数优化,提高了轨道电路传输长度。
7提高机械绝缘节轨道电路传输长度,实现与电气绝缘节轨道电路等长传输。
8轨道电路调整按固定轨道电路长度与允许最小道碴电阻方式进行。
既满足了1Ω²
km标准道碴电阻、低道碴电阻最大传输长度要求,又为一般长度轨道电路最大限度提供了调整裕度,提高了轨道电路工作稳定性。
9用SPT国产铁路数字信号电缆取代法国ZCO3电缆,减小铜芯线径,减少备用芯组,加大传输距离,提高系统技术性能价格比,降低工程造价。
10采用长钢包铜引接线取代75mm2
铜引接线,利于维修。
11系统中发送器采用“N+1”冗余,接收器采用成对双机并联运用,提高系统可靠性,大幅度提高单一电子设备故障不影响系统正常工作的时间。
3系统主要技术条件3.1环境条件
ZPW-2000A无绝缘移频轨道电路在下列环境条件下应可靠工作:
1周围空气温度:
室外:
-30℃~+70℃;
室内:
-5℃~+40℃2周围空气相对湿度:
不大于95%(温度30