IEC6060374插拔标准Word下载.docx
《IEC6060374插拔标准Word下载.docx》由会员分享,可在线阅读,更多相关《IEC6060374插拔标准Word下载.docx(44页珍藏版)》请在冰点文库上搜索。
•withdrawn;
•replacedbyarevisededition,or
•amended.
1Scope
ThisstandardcoversIEC60603-7-4connectors,andspecifiesmechanicalandenvironmentalrequirements,andelectricaltransmissionrequirementsforfrequenciesupto250MHz.Theseconnectorsaretypicallyusedascategory6connectorsinclassEcablingsystemsspecifiedinIS0/IECIS11801:
2002.
Theseconnectorsareintermateable,interoperable,andbackwardcompatiblewithotherIEC60603-7seriesconnectors.WhilethedefinitionofinteroperableisbeingdiscussedwithinIEC,“interoperable”inthisstandardmeansthefollowing:
ThefixedandthefreeconnectorarecapableofinterconnectingwithanyIEC60603-7seriesconnector,andthatwhenitisinterconnected,itfullymeetsallrequirementsofthelowerfrequency60603-7seriesstandard.
2Technicalinformation
Terminology
Theterminologyusedinandapplicabletothisspecificationisstatedin2.1ofIEC61076-1.SomeapplicabletermsarealsocoveredinIEC60512-1.
(Fordefinitionsoftermsused,refertoIEC60050(581).)
Transmissionperformancecategories:
InthisIECstandard,theterm“category”,whenusedinreferencetotransmissionperformance,referstothosecategoriesdefinedbyISO/IEC11801:
2.1Interchangeabilitylevel
Theseconnectorsareintermateable,interoperableandbackwardcompatiblewithIEC60603-7seriesconnectors.
2.2.1Intermateability
Intermateabilityisensuredbyapplyingthe“GO”and“NO-GO”gaugerequirementsherein,andadherencetodimensionalrequirementswithin.
2.2.2BackwardCompatibility
Thebackwardcompatibilityrequirementensuresthataplugorjackwhichisincompliancewiththisstandard,matedwithajackorplugincompliancewithanylowerfrequencyIEC60603-7seriesconnector,shallfullycomplywiththerequirementsofthelowerfrequencyIEC60603-7seriesconnector.
2.2.3Interoperability
InteroperabilityofdifferentIEC60603-7-4connectorsisassuredbycompliancewithalltransmissionrequirementswhenthefixedconnectorismatedwithafullrangeof“test”freeconnectors,or“testplugs”,asdescribedherein.
2.2IECtypedesignation
Connectors,connectorbodiesandconnectorswithpre-insertedcontactsaccordingtothisstandardshallbedesignatedbythefollowingsystem:
IEC-60603-7-4
L
N
Numberdenotingperformancelevel(PL)
1
750operations
2
2500operations
Referencetothisstandard
Lettersdenotingconnectortype
Fixedversion
A
Freeversion
C
Numberofcontacts
8
Letterdenotingtypeofcontact
Female
F
Male
M
Letterdenotingtypeoftermination
Crimp
Accessibleinsulationdisplacement
Non-accessibleinsulationdisplacement
Insulationpiercing
P
Solder
S
Springclamp
B
Pressinconnection
T
Screwterminal
NOTE“L”standsforletter
“N”standsfornumber
Numberdenotingcontactfinish
Gold,gold-alloy
Palladium/nickel
Numberdenotingvariant
Variant1
Letterdenotingtypeofconductoraccommodation,orcable
Strandedwire
Solidwire
E
Strandedorsolidwire
X
Customerspecificrequirementsforcables
G
Boardmounted
Tinselwire
D
Tinselorstrandedwire
Tinsel,stranded,orsolidwire
Example:
IEC60603-7-4A8FP-E11-1:
Fixedconnector,panelmounted,having8femalecontactsinstandardcontactpositions,goldplated,meetingperformancelevel1.
3CommonFeaturesandIsometricView
3.1Isometricview
Figure1
3.1Matinginformation
General
Dimensionsaregiveninmillimetres.Drawingsareshowninthirdangleprojections.Theshapeofconnectorsmaydeviatefromthoseshapesgiveninthefollowingfiguresaslongasthespecifieddimensionsarenotinfluenced.
Contacts–Matingconditions
Figure2–Contactinterfacedimensionswithterminatedfreeconnector
Notesforfigure2
Femalecontactoffixedconnector.Thematinginformationshowncanonlybeachievedwithafreeconnectorwithacableattached.
Burrsshallnotprojectabovetopofcontactinthisarea,sinceitmaybeacontactarea.
3
Optionalangle.
4
Preferredcontactinterfacedetail.
5
Minimumpreferredcontactconfiguration.
6
Preferredcontactconfiguration.
7
Optionalcontactconfiguration.
Tableau1Table1
Lettre
Maximum
Minimum
Letter
mm
A2
1,45
0,89
B2
0,61
0,51
C2
0,46
0,03
D2
2,79
E2
4,11
F2
6,22
H2
0,38
J2
0,64
K2
6,15
5,89
M2
0,30
N2
0,28
P1
0,50
0,45
P3
0,36
R2
4,83
G2
10°
Careshallbetakenthatthejackcontactsavoidinterferencewiththeplasticofthefreeconnector.
Freeconnector
Figure4
Notesforfigure4
Fullradiuspermittedonallslots.
Thesedimensionsapplytothelocationsofthecontactslots.
Applieswithlockingdevicedepressed.
CenterforS2,T2,andW2.
Tableau3Table3
Nominal(ref)
A21)
1)
1,17
B21)
0,56
S2
11,79
11,58
11,68
T2
3,38
3,12
W2
6,17
6,02
X2
5,77
Y2
2,34
Z2
2,06
AA2
1,24
AB2
AC2
6,71
6,50
6,60
AD2
0,13
AH2
1.02
AW2
AX2
1,32
AY2
2,87
2,67
AZ2
BA2
12,32
BB2
1,14
BC2
1,02
BD2
BE2
1,09
BF2
BG2
BH2
BL2
8,36
BM2
15,88
14,61
BN2
8,00
1)Voirtableau1
Seetable1
BJ2
Rayoncomplet
Fullradius
BK2
3°
30'
Cableterminationsandinternalconnections–FixedandFreeconnectors
Aconnectormayincludemultipleterminationsbetweenthecableterminationandtheseparablecontactinterface.ThesemayincludepressinconnectionsofjackspringsintoPCBs,forexample.Allterminationsshallmeettherelevantterminationrequirements.
IfatypeofsolderlessterminationisusedwhichisnotcoveredbyanyIECspecification,thesuppliershallassureitsreliabilitybyperformingsimilartests,anddemonstratingasimilarlevelofperformance,tothosein60352.
Freeconnectorsareintendedtobeterminatedtocabletoprovideconnectorandcableassemblies.Theconnectortypedesignationprovidesbasicterminationsconcerningthetypeofconductor(stranded,solid)towhichtheconductormaybeapplied,andthetypeofconnectionused(solder,insulationdisplacement,etc.).Specificdetailsconcerningwiregaugesize,typeandthick