海外石油钻井中级工程师考试题英文版.docx
《海外石油钻井中级工程师考试题英文版.docx》由会员分享,可在线阅读,更多相关《海外石油钻井中级工程师考试题英文版.docx(21页珍藏版)》请在冰点文库上搜索。
![海外石油钻井中级工程师考试题英文版.docx](https://file1.bingdoc.com/fileroot1/2023-7/8/bb17a299-bd93-4d7d-9533-d6c180603228/bb17a299-bd93-4d7d-9533-d6c1806032281.gif)
海外石油钻井中级工程师考试题英文版
TESTPAPER
FOR
MEDIUMDRILLINGTECHNICIAN
TABLEOFCONTENTS
OFTESTPAPERFORMEDIUMDRILLINGTECHNICIAN
TESTNO.
WORKDEFINITION
TYPE
PTS
Test1
StringtheBlockinOrdinarySequence
PrepareWorkPreSpudin
30
Test2
CalibrateWeightIndicator
PrepareWorkPreSpudin
30
Test3
InspectandMaintainManualTongs
Inspectionandmaintenance
30
Test4
CheckandReplaceMudPumpPiston
EquipmentComponentsReplacing
40
Test5
OperateChokeManifoldtostandby
EquipmentOperating
40
TESTGROUP1
WORKDEFINITION
TYPE
PTS
StringtheBlockinOrdinarySequence
PrepareWorkPreSpudin
30
CalibrateWeightIndicator
PrepareWorkPreSpudin
30
CheckandReplaceMudPumpPiston
EquipmentComponentsReplacing
40
Total
100
TESTGROUP2
WORKDEFINITION
TYPE
PTS
CalibrateWeightIndicator
PrepareWorkPreSpudin
30
InspectandMaintainManualTongs
Inspectionandmaintenance
30
OperateChokeManifoldtostandby
EquipmentOperating
40
Total
100
Test1StringtheBlockinOrdinarySequence(MastType:
A)
1.PreparationRequirement
1)MaterialPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
steelline
φ32mm
roll
1
2
whitecoirrope
φ25mm
meter
120
3
lineclamp
32mm
piece
4
2)EquipmentPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
derrickmodel
set
1
3)OtherToolsPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
crowbar
1200mm
piece
2
2
cuttingpliers
200mm
piece
1
3
adjustablewrench
300mm
piece
2
2.InstructionsofOperationandAssessment
(1)Operationprocedure
1)Preparation;
2)StringtheBlock;
3)Fasten(Fastendeadline3roundsaroundpulleyofdeadlineanchor,tightitwithpressboard,screwup6studs.Tie300mmlongsteellinetothedeadlineendwith2lineclamps,intervalbetween2clampsis50mm.Pulloutliveendofdrilllinefrominsideholeofdrawworksdrum,pullthroughlockplate,tie100mmlongsteellinetotheliveendwith2lineclamps,intervalbetween2clampsis50mm).
(2)InstructionsofTestRules
1)TestOfficerwillstoptheassessment,ifemployeeoperatesagainstrules.
2)Fullmarkofthistestis100points,thetestresultwilladdtogrouptestresultasperitsproportion.
3)Testtype:
operationtest,evaluatingaccordingtooperationprocedures.
4)Testpurpose:
thistestistotestemployee’sskillofstringingtheBlockinordinarysequence.
3.TestTime
(1)Preparetime:
1minute(notincludedinoperationtime)
(2)Operationtime:
10minute
(3)Noaddedpointsiffinishoperationwithinoperationtime,operationmustbestoppedafteritsdeadline.
TestRecordTable
Test1RecordTable
Name:
ID:
Position:
RigNo.:
SP-
TestTitle:
StringtheBlockinOrdinarySequenceTestTime:
10min
No.
Test
Definition
EvaluationElement
PTS
EvaluationStandard
Deduction
Score
remark
1
Preparation
Preparationofmaterialandtools
5
Eachmissingitemis0.5ptdeduction,butnomorethan5pts.
2
StringtheBlockinOrdinarySequence
Numbercrownblockpulleysfromdeadlinepulleylike1.2.3.4.5.6.
Numbertravellingblockpulleysneardeadlinelikea.b.c.d.e.
10
Eachwrongnumberforcrownblockpulleysortravellingblockpulleysis5ptsdeduction.
Takewhitecoirropeasguideline,connectittodrillline,pullguidelinethroughpulleyNo.1.
10
Wrongconnectionbetweenguidelineanddrilllineis5ptsdeduction.
WronglypullingthroughpulleyNo.1is5ptsdeduction.
PulldrilllinethroughpulleyNo.1andpulleyNo.a.
10
Wrongdirectionis5ptsdeduction.
Wrongpulleyis5ptsdeduction.
PulldrilllinethroughpulleyNo.2andpulleyNo.b.
10
Wrongdirectionis5ptsdeduction.
Wrongpulleyis5ptsdeduction.
PulldrilllinethroughpulleyNo.3andpulleyNo.c.
10
Wrongdirectionis5ptsdeduction.
Wrongpulleyis5ptsdeduction.
PulldrilllinethroughpulleyNo.4andpulleyNo.d.
10
Wrongdirectionis5ptsdeduction.
Wrongpulleyis5ptsdeduction.
PulldrilllinethroughpulleyNo.5andpulleyNo.e.
10
Wrongdirectionis5ptsdeduction.
Wrongpulleyis5ptsdeduction.
PulldrilllinethroughpulleyNo.6(fastlinepulley)todrawworksdrum.
10
Wrongpulleyis5ptsdeduction.
Wrongdirectionis5ptsdeduction.
3
Fasten
Pulldrillline(liveline)abitlengthfromdrawworksdrum,fastendeadlineheadandlivelinehead.
15
Notappropriateexcesslengthoflivelineis5ptsdeduction.
Eachloosenofdeadlineheadorlivelineheadis5ptsdeduction.
4
Ending
Cleanoperationsiteandputtoolsandmaterialback.
Notappropriateendingis5ptsdeduction.
5
Testtime
10minutes
Operationmustbestoppedafter10minutes.
Total
100
Testedby:
Checkedby:
(d)/(m)/2012
Test2CalibrateWeightIndicator
1.PreparationRequirement
1)EquipmentPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
drillingrig
set
1
2)MaterialPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
transformeroil
45#
Kg
5
3)OtherToolsPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
adjustablewrench
200mm
piece
1
2
manualpump
set
1
3
screwdriver
200mm
piece
1
4
pinextractor
set
1
2.InstructionsofOperationandAssessment
(1)Operationprocedure
1)Preparation;
2)Loosegasdischargescrewplugs.
3)CalibrateWeightIndicator
4)Cleaningsite
(2)InstructionsofTestRules
1)TestOfficerwillstoptheassessment,ifemployeeoperatesagainstrules.
2)Fullmarkofthistestis100points,thetestresultwilladdtogrouptestresultasperitsproportion.
3)Testtype:
operationtest,evaluateaccordingtooperationprocedure.
4)Testpurpose:
thistestistotestemployee’sskillofCalibratingWeightIndicator.
3.TestTime
(4)Preparetime:
1minute(notincludedinoperationtime)
(5)Operationtime:
10minute
(6)Noaddedpointsiffinishoperationwithinoperationtime,operationmustbestoppedafteritsdeadline.
TestRecordTable
Test2RecordTable
Name:
ID:
Position:
RigNo.:
SP-
TestTitle:
CalibrateWeightIndicator
No.
Test
Definition
EvaluationElement
PTS
EvaluationStandard
Deduction
Score
remark
1
Preparation
Preparationofmaterialandtools
5
EachMissingitemis2ptsdeduction,butnomorethan5pts.
2
LooseGasDischargeScrewPlugs,
ReleaseOilPressure
Laydownorsetoffdrillstringweight
10
Missingthisprocedureis10ptsdeduction.
Loosengasdischargescrewplugs,
Releaseoilpressure
5
WrongdirectionofLoosingscrewplugsis3ptsdeduction.
OilPressurerelieftoofastis2ptsdeduction.
3
CalibrateWeightIndicator
CalibrateWeightIndicatorneedles
10
Missingoneneedle’scalibratingis5ptsdeduction.
Loosenneedleis.
Nomorethan10ptsdeductioninthisitem.
Needlesworksmoothly
5
Nosmoothlyworkingofneedlesis5ptsdeduction
Connectlinestomanualpump,makeupandtightengasdischargescrewplugs.
10
Missingtoconnectmanualpumpis5ptsdeduction.
Missingtotightengasdischargescrewplugsis5ptsdeduction.
Pumptransformeroil
5
IfweightIndicatorindicatestoobigorsmallweight,itis5ptsdeduction.
CheckWeightIndicator,sensor,hydrauliclines.
15
Eachmissingcheckis5ptsdeduction.
Loosengasdischargescrewplugstoreleasegas
10
Releasinggastoofastis5ptsdeduction.
Ifneedlesarebacktowrongdirection,therewillbe5ptsdeduction.
Tightenscrewplugs.
Removemanualpumplines.
10
Ifscrewplugsarenottightentimely,it’s5ptsdeduction.
Ifmanualpumplinesarenotremovedatonetime,it’s5ptsdeduction.
Checkintervalunderplaten.
10
Missingcheckingsuspendingweightanddrillstringweightis4ptsdeduction.
Missingcheckingintervalunderplatenis4ptsdeduction.
4
Ending
Cleanoperationsiteandputtoolsandmaterialback.
Notappropriateendingis5ptsdeduction.
5
Testtime
10minutes
Operationmustbestoppedafter10minutes.
Total
100
Testedby:
Checkedby:
(d)/(m)/2012
Test3InspectandMaintainManualTongs
1.PreparationRequirement
1)EquipmentPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
ManualTong
TypeB
set
2
2)MaterialPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
tonginsert
piece
4
2
tongendrope
φ22mm
piece
2
3
Latchassembly
Set
1
4
splitpin
Piece
5
3)OtherToolsPreparation
Item
Name
Specification
Unit
Quantity
Remark
1
steelbrush
piece
1
2
adjustablewrench
200mm
piece
1
3
hammer
1.5kg
set
1
4
cuttingpliers
200mm
piece
1
2.InstructionsofOperationandAssessment
(1)Operationprocedure
1)Preparation;
2)CheckManualTong.
3)InspectandMaintainmanualtong.
(2)InstructionsofTestRules
1)TestOfficerwillstoptheassessment,ifemployeeoperatesagainstrules.
2)Fullmarkofthistestis100points,thetestresultwilladdtogrouptestresultasperitsproportion.
3)Testtype:
operationtest,evaluateaccordingtooperationprocedure.
4)Testpurpose:
thistestistotestemployee’sskillofInspectionandMaintenanceofManualTongs.
3.TestTime
(7)Preparetime:
1minute(notincludedinoperationtime)
(8)Operationtime:
10minute
(9)Noaddedpointsiffinishoperationwithinoperationtime,operationmustbestoppedafteritsdeadline.
TestRecordTable