TM-21Calculator表格推荐下载.xlsx
《TM-21Calculator表格推荐下载.xlsx》由会员分享,可在线阅读,更多相关《TM-21Calculator表格推荐下载.xlsx(5页珍藏版)》请在冰点文库上搜索。
ProjectingLongTermLumenMaintenanceofLEDLightSources.CalculatorresultshavebeenvalidatedbytheU.S.NationalInstituteofStandardsandTechnology(NIST).Calculationsarelocked;
onlydataentrycellsmaybemodified.Calculatorinputsareenteredonthesecondtab,withinstructions.Thecalculatormaybeusedwithone,twoorthreecasetemperatures.InputtingvaluesonthesecondtabgeneratesacompleteTM-21reportontheReporttab.Questionsmaybedirectedtoluminairesenergystar.govorlampsenergystar.gov.TM-21InputsLM-80TestInputsInstructionsDescriptionofLEDLightSourceTested(manufacturer,model,catalognumber)TestedCaseTemperature1TestedCaseTemperature2TestedCaseTemperature3Yellowfieldsarecompletedbytheuser.Fieldsnotusedshouldbeleftblank.Cyanfieldsarecalculatedbasedonuserentries.First,enteradescriptionoftheLEDlightsourcetested.ThencompletethefieldslabeledLM-80TestingDetails.Testdurationmustbeatleast6,000hours.Ifonlyonecasetemperaturedatasetistobeused(nointerpolation),completeonlyTestedcasetemperature1.Foronlytwocasetemperaturedatasets,complete1and2.Next,furthertotheright,inthecorrespondingbox(es)foreachtestedcasetemperature,enterthetestdataalongwiththetime(inhours)atwhicheachmeasurementwastaken.Dataenteredmustbenormalizedthenaveragedmeasureddata(perTM-21sections5.2.1and5.2.2).Enterdrivecurrent,in-situtemperaturedataandthepercentageofinitiallumenstoprojecttointhefieldslabeledIn-SituInputs.Resultscanbetailoredtoestimatelumenmaintenanceataspecifictimebyenteringavalue(t)intheyellowfield.AcompleteTM-21reportwillappearonthenexttablabeledReport.Time(hours)LumenMaintenance(%)Time(hours)LumenMaintenance(%)Time(hours)LumenMaintenance(%)LM-80TestingDetailsTotalnumberofunitstestedpercasetemperature:
Numberoffailures:
Numberofunitsmeasured:
Testduration(hours):
Testeddrivecurrent(mA):
Testedcasetemperature1(Tc,C):
Testedcasetemperature2(Tc,C):
Testedcasetemperature3(Tc,C):
In-SituInputsDrivecurrentforeachLEDpackage/array/module(mA):
In-situcasetemperature(Tc,C):
Percentageofinitiallumenstoprojectto(e.g.forL70,enter70):
ResultsTime(t)atwhichtoestimatelumenmaintenance(hours):
Lumenmaintenanceattime(t)(%):
CalculatedLM(hours):
ReportedLM(hours):
TM-21ReportTable1:
ReportateachLM-80TestConditionTable2:
InterpolationReportDescriptionofLEDLightSourceTested(manufacturer,model,catalognumber)(projectionbasedonin-situtemperatureentered)Ts,1(C)-Ts,1(K)-1-Samplesize-Samplesize-Samplesize-B1-Numberoffailures-Numberoffailures-Numberoffailures-Ts,2(C)-DUTdrivecurrentusedinthetest(mA)-DUTdrivecurrentusedinthetest(mA)-DUTdrivecurrentusedinthetest(mA)-Ts,2(K)-Testduration(hours)-Testduration(hours)-Testduration(hours)-2-Testdurationusedforprojection(hourtohour)-Testdurationusedforprojection(hourtohour)-Testdurationusedforprojection(hourtohour)-B2-Testedcasetemperature(C)-Testedcasetemperature(C)-Testedcasetemperature(C)-Ea/kb-A-B-B-B-B0-CalculatedL70(Dk)(hours)-CalculatedL70(Dk)(hours)-CalculatedL70(Dk)(hours)-Ts,i(C)-ReportedL70(Dk)(hours)-ReportedL70(Dk)(hours)-ReportedL70(Dk)(hours)-Ts,i(K)-i-ProjectedL70(Dk)(hours)-ReportedL70(Dk)(hours)-ReportGeneratedBy:
Notes:
Company:
Date: